Engine Model | Perkins® 1506A-E88TAG5 |
Bore | 112 mm (4.4 in) |
Stroke | 149 mm (5.9 in) |
Governor Type | Electronic |
Displacement | 8.8l (537 cu. in) |
Compression Ratio | 16.1:1 |
Engine Model | Perkins® 1506A-E88TAG3 |
Bore | 112 mm (4.4 in) |
Stroke | 149 mm (5.9 in) |
Governor Type | Electronic |
Displacement | 8.8l (537 cu. in) |
Compression Ratio | 16.1:1 |
Engine Model | Perkins® 404A-22G1 |
Bore | 84 mm (3.3 in) |
Stroke | 100 mm (3.9 in) |
Governor Type | Mechanical |
Displacement | 2.2l (135.2 cu. in) |
Compression Ratio | 23.3:1 |
Engine Model | Perkins® 1106D-E70TAG4 |
Bore | 105 mm (4.1 in) |
Stroke | 135 mm (5.3 in) |
Governor Type | Electronic |
Displacement | 7.0l (427.8 cu. in) |
Compression Ratio | 16.8:1 |
Engine Model | Perkins® 1106A-70TAG2 |
Bore | 105 mm (4.1 in) |
Stroke | 135 mm (5.3 in) |
Governor Type | Mechanical |
Displacement | 7.0l (427.8 cu. in) |
Compression Ratio | 16.0:1 |
Engine Model | Perkins® 1106A-70TG1 |
Bore | 105 mm (4.1 in) |
Stroke | 135 mm (5.3 in) |
Governor Type | Mechanical |
Displacement | 7.0l (427.8 cu. in) |
Compression Ratio | 18.2:1 |
Minimum Rating | 100 kVA / 80 kW |
Maximum Rating | 125 kVA / 100 kW |
Emissions/Fuel Strategy | Fuel Optimised |
50 Hz Prime | 100 kVA / 80 kW |
50 Hz Standby | 110 kVA / 88 kW |
60 Hz Prime | 113 kVA / 90.4 kW |
60 Hz Standby | 125 kVA / 100 kW |
Frequency | 50 / 60 Hz |
Speed | 1500 or 1800 RPM |
Voltage | 110-480 Volts |
50 Hz Prime Rating | These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. |
60 Hz Prime Rating | These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). |
50 Hz Standby Rating | Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. |
Perkins 13KVA Diesel Silent Generator Heavy Duty 3phase
Minimum Rating | 10 kVA / 10 kW |
Maximum Rating | 13 kVA / 13 kW |
Emissions/Fuel Strategy | EU3a Emissions Compliant |
50 Hz Prime | 10 kVA / 10 kW |
50 Hz Standby | 11 kVA / 11 kW |
60 Hz Prime | 12 kVA / 12 kW |
60 Hz Standby | 13 kVA / 13 kW |
Frequency | 50 / 60 Hz |
Speed | 1500 or 1800 RPM |
Voltage | 415 Volts |
Minimum Rating | 10 kVA / 10 kW |
Maximum Rating | 13 kVA / 13 kW |
Emissions/Fuel Strategy | EU3a Emissions Compliant |
50 Hz Prime | 10 kVA / 10 kW |
50 Hz Standby | 11 kVA / 11 kW |
60 Hz Prime | 12 kVA / 12 kW |
60 Hz Standby | 13 kVA / 13 kW |
Frequency | 50 / 60 Hz |
Speed | 1500 or 1800 RPM |
Voltage | 220-240 Volts |
50 Hz Prime Rating | These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. |
60 Hz Prime Rating | These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). |
50 Hz Standby Rating | Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. |